Welcome to khandelwal Distributors

VRV Home

BRAND: Daikin

Open doors to an incredible air conditioning solution for your home by Dakin ā€“ VRV Home, that replaces multiple outdoor units of your house with a single outdoor unit. From its quiet and efficient Swing Compressor to unmatched Design Flexibility, and best-in-class Comfort, it lets you experience the style, power and flexibility of the Daikinā€™s next-gen air conditioning system. Khandelwal Distributors is a Prominent and authorised Distributors and Dealers of Dekin VRV Home in Bareilly. We Distribute Dekin VRV Home in Moradabad, Amroha, Chandausi, Ujhani, Badaun, Pilibhit, Shahjahanpur, Lakhimpur, Hardoi, Sitapur, Puranpur, Paliya, Ghaziabad, Hapur, Khatima, Rudrapur, Kashipur and Noida. Just Contact us and Get Quotes.


  • Slim Ceiling Mounted Duct Type
  • Suited to use in Drop-Ceilings
  • Mid Static Pressure Ceiling Mounted Duct Type
  • Wall Mounted Type
$239.00

VRV OUTDOOR UNIT

An apartment or a house that does not have sufficient space will find difficult to accommodate numerous outdoor units. Even if the outdoor units are somehow crowded together they will consume a lot of space, look cluttered and ruin the aesthetics of the house.

VRV Home replaces all the outdoor units of the house with just one outdoor unit. A total of 8 indoor units can be connected to one outdoor unit to create the space you have always desired. Also you have different styles of indoor units like duct type and hi-wall that can be connected with a single outdoor unit. Furthermore, actual piping length of up to 40 meters coverage of widespread spaces is ensured.

The trunk-shaped outdoor unit can be easily be installed on a balcony, realizing complete system installation within each floor. While the compact outdoor unit can be hanged on the wall eliminating need for floor space, which enables more useful utilisation of the space on the building rooftop.

Outdoor unit can be selected from six models to provide the power that suits your needs. The trunk-shaped outdoor unit can be neatly installed outside.

It can also be hanged on the wall, consequently, eliminating the need for floor space. This enables a more useful utilization of the space on the building rooftop.

Heat Pump Series

Model Name

RXYRQ4ARV16

RXYRQ5ARV16

RXYRQ6ARV16

Capacity Range

4 HP (11.2 kW)

5 HP (14.0 kW)

6 HP (16 kW)

 

Cooling Only Series

Model Name

RXRQ4ARV16

RXRQ5ARV16

RXRQ6ARV16

Capacity Range

4 HP (11.2 kW)

5 HP (14.0 kW)

6 HP (16 kW)

 

Specification

Slim Ceiling Mounted Duct Type (700 mm width type)

MODEL WITH DRAIN PUMP

 

FXDRQ20PDV36

FXDRQ25PDV36

FXDRQ32PDV36

Power supply

 

1-phase, 220V / 240V, 50 Hz

Cooling capacity

Btu/h
kW

7500
2.2

9600
2.8

12300
3.6

Heating capacity

Btu/h
kW

8500
2.5

10900
3.2

13600
4

Casing

 

 

Galvanised steel plate

 

Airflow rate (HH/H/L)

m3/min
cfm

8.0/7.2/6.4
282/254/226

8.0/7.2/6.4
282/254/226

8.0/7.2/6.4
282/254/226

External static pressure

Pa

30-10 *2

Sound level (HH/H/L)*1 *3

dB(A)

33/31/29

33/31/29

33/31/29

Dimensions (HxWxD)

mm

200x700x620

200x700x620

200x700x620

Machine weight

kg

23

23

23

Piping connections

Liquid (Flare)
Gas (Flare)
Drain

mm

6.4
12.7

6.4
12.7

6.4
12.7

 

 

 

VP20 (External Dia, 26/Internal Dia, 20)

 

Slim Ceiling Mounted Duct Type (900/1,100 mm width type)

MODEL

WITH DRAIN PUMP

FXDRQ4ONDV36

FXDRQ5ONDV36

FXDRQ63NDV36

Power supply

1-phase, 220V / 240V, 50 Hz

Cooling capacity

Btu/h
kW

15400
4.5

19100
5.6

24200
7.1

Heating capacity

Btu/h
kW

17100
5

21500
6.3

27300
8

Casing

 

 

Galvanised steel plate

 

Airflow rate (HH/H/L)

m3/min
cfm

10.5/9.5/8.5
371/335/300

12.5/11.0/10.0
441/388/353

16.5/14.5.13.0
583/512/459

External static pressure

Pa

40-15*2

 

 

Sound level (HH/H/L)*1 *3

dB(A)

34/32/30

35/33/31

36/34/32

Dimensions (HxWxD)

mm

200x900x620

200x900x620

200x1,100x620

Machine weight

kg

27

28

31

Piping connections

Liquid (Flare)
Gas (Flare)
Drain

mm

6.4
12.7

6.4
12.7

9.5
15.9

 

 

 

VP20 (External Dia, 26/Internal Dia, 20)

 

 

Specifications are based on the following conditions:

  • Cooling: Indoor temp.: 27 DB, 19 WB, Outdoor temp.: 35 DB, Equivalent piping length: 7.5 m, Level difference: 0 m.
  • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
  • Heating: Indoor temp.: 20 DB, Outdoor temp.: 7 DB, 6 WB, Equivalent piping length: 7.5 m, Level difference: 0 m.
  • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

  • Values are based on the following conditions: FXDRQ-PD: external static pressure of 10 Pa; FXDRQ-ND: external static pressure of 15 Pa.
  • External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard" (Factory setting is 10 Pa for FXDRQ-PD models and 15 Pa for FXDRQ-ND models.)
  • The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).

 

Mid Static Pressure Ceiling Mounted Duct Type

MODEL WITH DRAIN PUMP

FXMRQ40ARV16

FXMRQ50ARV16

FXMRQ63ARV16

FXMRQ80ARV16

FXMRQ100ARV16

Power supply

1-phase, 220V / 240V 50 Hz

Cooling capacity

Btu/h
kW

15,400
4.5

19,100
5.6

24,200
7.1

30,700
9.0

38,200
11.2

Heating capacity

Btu/h
kW

15,400
4.5

19,100
5.6

24,200
7.1

30,700
9.0

38,200
11.2

Casing

 

 

 

Galvanised steel plate

Airflow rate (H/L)

m3/min
cfm

15/12
530/425

19/16
671/565

24/20
848/706

30/25
1060/883

34/29
1200/1024

External static pressure

Pa

30-50

30-50

30-50

30-50

30-50

Sound level (H/L)

dB(A)

39/37

41/39

42/40

43/41

33/44/42

Dimensions (H xWx D)

mm

300x700x700

300x700x700

300x1000x700

300x1000x700

300x1000x700

Machine weight

kg

27

28

35

35

36

Piping
connections

Liquid (Flare) Gas (Flare) Drain

mm

6.4
12.7

6.4
12.7

9.5
15.9

9.5
15.9

9.5
15.9

VP25 (External Dia, 32/Internal Dia 25)

 

 

 

 

 

 

Specifications are based on the following conditions:

  • Cooling: Indoor temp.: 27Ā°CDB, 19Ā°CWB, Outdoor temp.: 35Ā°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
  • Heating: Indoor temp.: 20Ā°CDB, Outdoor temp.: 7Ā°CDB, 6Ā°CDB Equivalent piping length: 7.5 m, Level difference: 0 m.
  • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
  • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

 

Wall Mounted Type

MODEL

FXARQ20ARVE6

FXARQ25ARVE6

FXARQ32ARVE6

FXARQ40ARVE6

FXARQ50ARVE6

FXARQ63ARVE6

Power supply

1-phase, 220V / 240V 50 Hz

Cooling capacity

Btu/h
kW

7,500
2.2

9,600
2.8

12,300
3.6

15,400
4.5

19,100
5.6

24,200
7.1

Heating capacity

Btu/h
kW

8,500
2.5

10,900
3.2

13,600
4.0

17,100
5.0

21,500
6.3

27,300
8.0

Casing

 

 

 

White (N9.5)

Airflow rate (H/L)

m3/min
cfm

7.5/4.5
265/159

9/5
318/177

11/5.5
388/194

13/9
459/318

15/12
530/424

19/14
671/494

Sound level (H/L)

dB(A)

35/31

36/31

38/31

39/34

42/37

47/41

Dimensions (H xWx D)

mm

298X929X258

298X929X258

298X929X258

298X929X258

298X929X258

298X929X258

Machine weight

kg

13.0

13.0

13.0

13.0

13.0

13.0

Piping
connections

Liquid (Flare) Gas (Flare) Drain

mm

6.4
12.7

6.4
12.7

6.4
12.7

6.4
12.7

6.4
12.7

9.4
15.9

VP13 (External Dia, 18/Internal Dia 13)

 

 

VRV OUTDOOR UNIT

Model

Cooling only

Heat Pump

RXRQ4ARV16

RXRQ5ARV16

RXRQ6ARV16

RXYRQ4ARV16

RXYRQ5ARV16

RXYRQ6ARV16

Power Supply

220-240V & 50Hz, 1 Phase

220-240V & 50Hz, 1 Phase

Cooling Capacity(kW)

11.2

14.0

16.0

11.2

14.0

16.0

Heating Capacity(kW)

-

-

-

11.2

14.0

16.0

Casing Color

Ivory White

Ivory White

Dimension (H*W*D)

990*940*320

990*940*320

Heat Exchanger

Cross Fin Coil(multi slit)

Cross Fin Coil(multi slit)

Fan

Type

Propeller Fan X1

Propeller Fan X1

Motor Output(W)

200

200

Air Flow Rate (m3/min)

76

76

Drive

Direct Drive

Direct Drive

Connecting Pipes

Liquid Pipe(Flare Connection)

9.5

9.5

Gas Pipe (Flare Connection)

15.9

15.9

Max actual pipe length (m)

40

40

Total Pipe length (m)

100

100

Weight (kg)

72

72

79

73

73

82

Sound pressure level dB(A)

52

54

55

52

54

55

Capacity control(%)

24-100

16-100

24-100

16-100

Combination ratio(%)

50-140%

Temp range Cooling(CDB)

0 to 49

0 to 49

Temp range Heating(CDB)

NA

0 to 20

Refrigerant Type

R410A

R410A

R410A

R410A

R410A

R410A

Compressor Type

Hermetically Sealed Swing Type

  • Slim Ceiling Mounted Duct Type
  • Suited to use in Drop-Ceilings
  • Mid Static Pressure Ceiling Mounted Duct Type
  • Wall Mounted Type

Add a Review

Your email address will not be published. Required fields are marked *

1 2 3 4 5
ss